Notifications
You must be signed in to change notification settings - Fork 7
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Merge pull request #128 from tetrabiodistributed/update-documentation…
…-for-makerfaire Update documentation for makerfaire
- Loading branch information
Showing
15 changed files
with
1,320 additions
and
21 deletions.
There are no files selected for viewing
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
File renamed without changes.
File renamed without changes.
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
File renamed without changes.
File renamed without changes.
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,39 @@ | ||
--- | ||
title: "PAPRa N100 Testing Guide (March 2024 Edition)" | ||
linkTitle: "PAPRa N100 Testing Guide (March 2024 Edition)" | ||
weight: 1 | ||
description: > | ||
How we tested the PAPRa to arrive at claims of N95/N99 levels of protection | ||
--- | ||
|
||
:note-caption: :information_source: | ||
:warning-caption: :warning: | ||
|
||
== Quick Synopsis | ||
|
||
In April of 2024, we began testing PAPRa units with a Portacount. This device enables the user to perform a fit test, and the unit designed for April 2024 passes above the 1000 grade needed for N100 (even though the user has a beard). | ||
|
||
|
||
[link=https://photos.smugmug.com/Tetra-Testing/N100-Testing/i-DJsvpT8/0/CnC5R6wTn8M6fnBCnSPQJrRjBTvtN5ffPMxcN3r58/M/PXL_20240311_000223904-X5.jpg] | ||
image::https://photos.smugmug.com/Tetra-Testing/N100-Testing/i-DJsvpT8/0/CnC5R6wTn8M6fnBCnSPQJrRjBTvtN5ffPMxcN3r58/M/PXL_20240311_000223904-L.jpg[] | ||
|
||
One of the right angle connectors to the mask was replaced with a version with a tap to connect to a hose to sample inside the mask, shown here on the right side of the image. | ||
|
||
[link=https://photos.smugmug.com/Tetra-Testing/N100-Testing/i-BjhXKSr/0/C8JwXtJgH6BJMN3qQVCKk2s6SsmRDtXNhxQRdJRRh/X5/PXL_20240311_000228987-X5.jpg] | ||
image::https://photos.smugmug.com/Tetra-Testing/N100-Testing/i-BjhXKSr/0/CvGV8VfwwPcwW4BGmBSWZqMKCmxWgdVTmgK9nJ7Tj/L/PXL_20240311_000228987-L.jpg[] | ||
|
||
We also tested a partially assembled version of the fan box using Honeywell N100 filters, that also passed as a device, but we did not perform a full fit test. | ||
|
||
[link=https://photos.smugmug.com/Tetra-Testing/N100-Testing/i-zt293Rp/0/D9TzgRV7f6LRnwDLdKc7hH7nvtBXRK6JjpZfGKhft/L/PXL_20240311_000538502-X5.jpg] | ||
image::https://photos.smugmug.com/Tetra-Testing/N100-Testing/i-zt293Rp/0/D9TzgRV7f6LRnwDLdKc7hH7nvtBXRK6JjpZfGKhft/L/PXL_20240311_000538502-L.jpg[] | ||
|
||
Trying to use the same Honeywell box with the larger VOC filters may have cracked the box, and so those filters did not pass: | ||
|
||
[link=https://photos.smugmug.com/Tetra-Testing/N100-Testing/i-zt293Rp/0/D9TzgRV7f6LRnwDLdKc7hH7nvtBXRK6JjpZfGKhft/L/PXL_20240311_000538502-X5.jpg] | ||
image::https://photos.smugmug.com/Tetra-Testing/N100-Testing/i-zt293Rp/0/D9TzgRV7f6LRnwDLdKc7hH7nvtBXRK6JjpZfGKhft/L/PXL_20240311_000538502-L.jpg[] | ||
|
||
We have stopped using pressure and flow tests, but instead simply rely on fit tests at this time. | ||
|
||
== WARNING | ||
|
||
Before you wear a PAPRa in any kind of potentially hazardous situation, it is critical that you test it to ensure that the unit is performing at an adequate level. We have personally worn these units for many hours and tested these units to ensure an N99 level of performance, but we cannot guarantee that the units you make will perform at the same levels. We provide no warranty, implicit or explicit, that any such units will provide protection. Please make sure to test your units accordingly and to your own level of comfort and in compliance with whatever local regulations require. |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,37 @@ | ||
|
||
--- | ||
title: "PAPRa Build Guide (April 2024 Edition)" | ||
linkTitle: "PAPRa Build Guide" | ||
weight: 1 | ||
description: > | ||
How to build the April 2024 version of the Tetra PAPR. | ||
aliases: | ||
- /v1.1 | ||
- /1.1 | ||
--- | ||
|
||
== Quick Synopsis | ||
|
||
This guide will walk you through how to build a Powered Air Purifying Respirator, also known as a PAPR. We assume that you have some knowledge of 3D-printing, and cutting foam with a knife or using a stencil or a cricut, and perhaps some soldering. In the end, you will have four things: a box with a filter and a fan in it, a second box with batteries and a fan controller, a mask, and straps and hoses to hold it all together. | ||
|
||
Please note that this system will not protect you from anything landing in your eyes. For that protection, either the mask will need to be modified to be a helmet or you will need a face shield. | ||
|
||
*WARNING:* we provide no warranty, implicit or explicit, that this device will work up to an N95 specification, a P100 specification, or any other standard, when built outside of a facility rated to do so. The only way to truly test one of these devices using something like a https://tsi.com/products/respirator-fit-testers/portacount-respirator-fit-tester-8038/[Portacount] under controlled conditions. | ||
|
||
Please refer to the link:testing-guide[Testing] section for the flow and fit testing done to verify PAPR functionality. | ||
|
||
== Parts needed | ||
|
||
The entire set of parts to build the PAPR is: | ||
|
||
|
||
image::https://photos.smugmug.com/Tetra-Testing/Makerfaire-2024-prep/i-7gHgdbp/0/CnwKx63gh5ph4jtLts36mSZ64z686WqJQXq5X4H4V/X3/DSCF0197-X3.jpg[] | ||
|
||
There are three components to build: | ||
|
||
1. link:m12-controller[The M12 Controller] | ||
2. link:fan-box[The Fan Box] | ||
3. link:mask[The Mask] | ||
|
||
And the instructions to build all of these components can be found in the Tetra PAPRA Components section. | ||
|
Oops, something went wrong.